by admin

Flow Dynamics Smart Valve

Flow Dynamics is not only the INDUSTRY LEADER in flow management technology, we INVENTED it! Since being awarded the original technology patent in 2014, others have tried to imitate but nobody has been able to duplicate the success of the Smart Valve. THE SMART VALVE™ FROM FLOW DYNAMICS, LLC. UTILITY MANAGEMENT, LTD, a division of Cooperative Holding Corporation,( a private-family owned investment and property management company with a highly successful 35 year history) is a Nationwide distributor of THE SMART VALVE ™ – a space age, patented, water and money saving valve, with a remarkable record of reducing your cost of.

Full game of thrones map

  1. Water Saver Valve
Smart valve patent

Water Saver Valve

Congratulations on purchasing the most advanced, micro processor controlled, hot water recirculation pump control made. This system is designed to run the recirculation pump only when you need it thus saving both water and energy. It is designed and built with pride in the USA to provide years of service and savings.
Contents:
1 Smart Recirc Control unit
2 Temperature Sensors (connected together)
1 ¾' NPT or 1' NPT Flow Meter
1 Wiring Harness
Needed:
The following items are needed for the installation, but are not included.
Electrical Tape

PTFE (Teflon) Tape
Wire fasteners for securing wiring to the wall
Specifications:
Input: 110VAC-220VAC/50Hz - 60Hz
Output: 110VAC-220VAC/50Hz - 60Hz
Max pump size: 1/2 hp
Please read over the following instructions. If you are not comfortable with any part of them please contact a licensed plumber to perform the installation.
Prior to installation please perform the following system test to ensure the unit is working prior to installing the flow meter.
1. Connect the wiring harness to the controller.
2. Connect the temperature sensors to the wiring harness ensuring they snap together securely.
3. Connect the flow meter to the wiring harness.
4. Plug the controller into a wall outlet and ensure that the LED on the side of the controller flashes green 3 times. If it doesn't but instead rapidly flashes red, see trouble shooting item 1 at the end of these instructions.
5.Gently blow through the flow meter in the direction of the arrow and ensure the controller makes a slight audible click and the red LED turns on for approximately 10 seconds. This test ensures that the controller, flow meter, temperature sensors and wiring harness are good and functional. If this test fails, please contact customer support via the Contact Us page.
Installation:
1. Note setting of water heater thermostat and then set to lowest temperature setting (do not turn off the pilot light).
2. Shut-off the cold water supply to the water heater.
3. Open the closest hot water faucet to the water heater. This helps drain the pressure from the heater and empty some of the water from the tank. Close the faucet when the line begins to sputter.
4. Lift the small lever on top of the pressure relief value to release any pressure left in the tank. You can find the relief value on the top of the tank or along the side.
5. Disconnect cold water supply line from water heater. Be careful not to bend and crease the supply line when manipulating it. Be prepared with some towels as some water will flow out, but you shouldn't have to drain the tank and/or the hot water loop.